Harbor Freight Rikonstein Dc - Product Reviews

Wednesday, 3 July 2024

I had to raise the filter/bag bracket to make all this work. I did this to try and delay, for a little while, replacing the HF with a real DC. That will be the last step, if necessary. I went with a Wynn Environmental 35a spun bond poly long ago, but there are newer less expensive options nowadays. You can also easily shop our recommended products here. Since the flex pipe is exactly 4" it won't fit over the 4" PVC. The only thing I might do is to caulk a joint if it appears to not be sealed well. I went one piece at a time, figuring out the best place for the wye. It became clear to me that I needed to build a dust collector so I finally built one for the Gray House Studio shop by taking a Harbor Freight dust collector and upgrading it to a 2 stage cyclone dust collector.

  1. Harbor freight dust collector impeller upgrade your browser
  2. Harbor freight 2hp dust collector impeller upgrade
  3. Harbor freight dust collector impeller upgrade parts
  4. Harbor freight dust collector impeller upgrade
  5. Harbor freight dust collector impeller upgrade your flash player

Harbor Freight Dust Collector Impeller Upgrade Your Browser

Duct tape at one end of the flex pipe to compress the pipe is the solution to reduce slack. With my pipe brackets, everything stays in place. The dust collector build started with a stock 2hp single phase Harbor Freight dust collector. A total of 8 srews holding it on. The flange provides an object to clamp. Styrene to box out table saw, band saw, router. The modifications to the dust collector are.... - Replace the 20 micron bag filter with a. Also, the other side of the gate will connect to the 4" flex hose or a 4" to 2. Before: the average at all three drops was 325 cfm After: average 640 cfm. 5" flex pipe and from the flex pipe to equipment. Since the tools are separated by 10 to 20 feet I needed more power than the Harbor Freight dust collector could provide.

1/2" MDF for the Gate Body and handles. Use PVC sewer and drain pipe instead of the heavier, more expensive schedule 40 PVC. All of the online tests of this modification alone show increased CFM of at least 35%, and static pressure (vacuum) increases of at least 10%. Keep the trust washer with the screw in the orientation it came off. My thought process here is to go with 6" mains, and keep my 4" branches / blast gates. The gasket may stick to the flange, or the impeller housing. A mandatory upgrade is the filter. The swap was easy, remove 12 screws for the impeller cover, remove a reverse threaded hex bolt and washer. Coat the inside of the bore and keyway of the new impeller with a light oil. In this tutorial we will show how we upgraded a Harbor Freight Dust Collector with the Super Dust Deputy XL from Oneida Air Systems. I used masonry anchors to attached 3/4" plywood to the wall to mount the motor. I started with the 2 HP Harbor Freight dust collector. You want to caulk last in case you need to move/change/undo the layout.

Harbor Freight 2Hp Dust Collector Impeller Upgrade

I used contact cement to glue the ends of EVA foam together. However, it does make the motor work more, using a amp clamp meter, here is what I found. The pipe had to be higher than 36" to clear my counter, which meant the Thien baffle had to be above 36". My now old, circa 2009 Central Machinery 2HP dust collector that I bought from Harbor Freight on sale and with a 20% off coupon, has always worked okay, but I want more than okay. I used the supplied HF pipe to connect the impeller to the collector bag in a straight run that is ~4" long, avoiding the longer curve of the out of the box setup. It is a little louder than before and a slightly different tone.

I had to grind down the screws since they were too long and would hit the impeller. In case anyone's been looking to upgrade their HF 2hp dust collector to a bigger impeller and having trouble finding the actual part, Wen's impeller is back in stock. Participated in the.

Harbor Freight Dust Collector Impeller Upgrade Parts

Rotate the impeller several times insuring no operational interference.. - Match original flange to new flange back to back. The cyclone comes with hardware to mount the cyclone and a gasket. I created a circle cutting jig for the of my gates had too much resistance to slide smoothly after glue up of the body. At each branch/Wye, you need a blast gate to close loops and maximize air flow suction. To determine if you have a 20 amp receptacle, they have a horizontal slot branching off one of the vertical slots. Remove the attachment screws for the flange. The Super Dust Deputy XL cyclone is designed to mount directly to the lid of the barrel.

I added an adapter which was 4" PVC with 5/8" cut out of it. The motor outlet will feed directly to the filter bag. Anyone know how to source this up? Have the gate closed while doing this so you don't encroach upon the blade path. It's unlikely static build up will start a fire. Prior to last upgrade. My DC uses 5" duct, reduced to 4" at three drops, it is ducted through a Super Dust Deputy and exhausts outside. At the belt sander I used a 45* elbow that directs right at the top. This model is no longer available, and Wynn has gotten expensive recently. I cut out a plywood flange as the dust collector body slopes. The housing cover doesn't deflect like I was worried, so that isn't an issue. The inside clear height is 4. Before: Startup amps, 14. I chose this trash can as I'm putting my dust collection in a corner, and I have to maintain a certain width.

Harbor Freight Dust Collector Impeller Upgrade

I am looking to save space, so instead of staying with my 55 gallon Thien separator, I am going to go with a Thein baffle in the separator ring of the dust collector. You may want to use Wynn's floating gear latches to secure the filter, or possibly come up with your own rig. I then used a wire cutter to cut through the wire. Personally I think the best mod you can make would be for air flow. I thought it was going to be a perfect fit, but I didn't read into it and just assumed. The trash can sits on a plywood sheet bolted to a scissor jack. I glued it to the top at the same time I caulked the channels for the side and tightened the nuts down for a tight fit. The Rikon P60-200-22 impeller seems to be the recommended replacement, but it appears to no longer be available. There are 2 that I know of, one from Rikon that has been next to impossible to get, and when available costs almost as much as the dust collector, and one from Wen, the 3403-22 Turbofan. Noise dropped by 3db to 93 db at 3 feet and 87 db at 6 feet.

5" 1/4" MDF spacers/sides. The bag will catch any particles that makes it though the blower to the filter. Unfortunately I don't have a lot to put towards something, but does anyone have any suggestions for a minor step up? 75" in one pass was too much strain on the router. Since I was doing electrical work in the shop at that point anyway, it wasn't a major issue. A ring with a 17" outer diameter was glued to the bottom. Gray House Studio does receive commissions for sales from these links but at no extra cost to you. 2 HP Dust Collector. If I could box it out it would perform even better.

Harbor Freight Dust Collector Impeller Upgrade Your Flash Player

After coming up short, it seems a 1. Make it Move Challenge. The 6″ hose fits nicely over the HVAC connector I bought. Attaching this piece made the cover a little stiffer. What is a good source for 6" DWV pipe and fittings? A clean filter maximizes air flow. It snapped trying to fit it to a 17" diameter. Whether I do depends on whether/how much I get shocked. 5" flex pipe, not realizing the mismatch in size. 5" long PVC pipe to caulk into each side of the gate. To dump the trash can, I bolted 3/4" plywood to the smallest scissor jack I had on hand. I put my dust collector in the garage, so I wasn't to worried about the fine particles, and I just put a big bag (6' long 24" diameter) on the system. After the hose (Flexaust 6″ X 5 feet hose from Amazon) and adapter were attached I wrapped it with Foil Tape to make it air tight. The standoffs the original poster used are a bit on the big side, but the idea is right there.

Cut List (each): (2) 6.