Water Technologies Water Softener Parts

Thursday, 11 July 2024
If you're experiencing an issue with your system, here's a water softener troubleshooting guide to help you identify the problem and either fix it yourself or call a pro. Greenway Water Conditioners are precision built, high quality products. ADVANCE CABINET SERIES WATER SOFTENER MANUAL. For the purpose of filling the softener, leave the unit in the bypass position until the 4th step, then repeat steps 1-6 with the unit full. 25 Drawings & Service Manual 1" Control Valve Series Model: WS1 1. Untreated supply water is allowed to flow to the system and to the building, while not allowing water to exit from the system to the building (Fig. The brine tank is manufactured for the use of solar, pellets or rock salt.
  1. Manual for water softener
  2. Water care water softener manual
  3. Water technologies water softener manual pdf
  4. Water technologies water softener manual.html
  5. Water technologies water softener parts
  6. Water technologies water softener manual available
  7. Water technologies water softener systems

Manual For Water Softener

If what you're searching for isn't found, please feel free to contact us. If your water tastes salty, the system is using too much salt — or there may be a clog in the drain hose which doesn't allow all the brine water to be properly flushed away. Check to be sure your water softener is plugged in and that the outlet is hot. Press next to complete and return to normal operation.

Water Care Water Softener Manual

Note: influent waters must be at least 3 GPG hardness and 80 TDS. M anual Regeneration: Sometimes there is a need to regenerate the system sooner than when the system calls for it, usually referred to as manual regeneration. STEP 3 Day Override: When gallon capacity is set to off, sets the number of days between regenerations. F. broken piston retainer G. broken main or regenerant piston 7. Allow to run until steady, clear and without air. System/Owners Manual. Water flows through the control valve for normal operation of a water softener or filter. This allows the service technician to draw brine and perform other tests without the test water going to the building. 7°C) · electrical 110 - 50/60Hz uninterrupted outlet · the tank should be on a firm level surface · current draw is 0.

Water Technologies Water Softener Manual Pdf

Press next to exit Installer Displays/Settings. Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being backsiphoned into the conditioner. Ft. ) Maximum Water Hardness (GPG) 2Maximum Iron (PPM) 3Minimum pH Required 4Peak Flow Rate (GPM @ PSI) Continuous Flow Rate (GPM @ PSI) Water Pressure Range (PSI) Operating Temperature Range (°F) Electrical Requirements (volts-hertz) Pipe Size Total Dimensions: Media Tank Depth GACS835 21, 000 @ 9. Valve does not regenerate automatically when regen button is depressed A. defective PC board CORRECTION A. replace motors B. repair outlet or use working outlet C. replace PCboard E. replace gear or drive cap assy. Timer does not display time of day A. transformer unplugged B. no power at outlet C. defective transformer D. defective PC board A. reconnect transformer B. repair or use working outlet C. replace transformer D. Manual for water softener. replace PCboard 2. The control valve may be stepped through the various regeneration cycles by pressing the regen button. A calcite or corsex unit may be needed for correct operation. Be sure that you closely follow all instructions and if you have any questions, give us a call. If backwash is shown in window, proceed to step 2b. Close the bypass valve.

Water Technologies Water Softener Manual.Html

Internal "O" Rings can easily be replaced if service is required. Or, make provisions in the plumbing system for a bypass. STEP 5 Next Regeneration Time (Minutes): Set the minutes of day for regeneration using the s or t buttons. Pressing next will alternate between the displays. To access this mode, press set clock.

Water Technologies Water Softener Parts

Yes, the regeneration process "revives" the resin beads so they can continue cleaning more water, but the older your softener, the less life it has. Teflon® tape is not used on the nut connections or caps because "O" Ring seals are used. The default is 20 with value ranges from 1 to 150 in 1 grain increments. If you don't find what you need here, you can always email us at or call 1-800-608-8792. ERROR If the display toggles between "Error" and an error code (i. a number), call a service technician and report the error code. Solder joints should be cool and solvent cements should be set before installing the nut, split ring and "O" Ring. Any changes made prior to the exit are incorporated. Water technologies water softener parts. 3 The pH listed is the minimum for the influent water. Our US Water Systems are designed to be effective, user-friendly, and long-lasting. For Immediate Regeneration: Press and hold regen until valve motor starts (typically 3 seconds).

Water Technologies Water Softener Manual Available

Power Loss: If the power goes out for less than two hours, the system will automatically reset itself. Valve does not regenerate automatically but does when regen button is depressed 9. Bypass Position: The inlet and outlet handles point to the center of the bypass. Each of these can be viewed by pressing next to scroll through them. Time of day flashes on and off A. bypass valve not in normal operating mode A. Water Softener Troubleshooting - Identify and Fix. see bypass diagrams on page 2 B. meter disconnected C. obstructed meter turbine D. defective meter E. programming error F. Power has been out more than two hours. Maintaining an optimal salt level is the best "fix" here. Water quality may vary. Making internal changes to the system's operation will affect how it operates and may affect its functionality.

Water Technologies Water Softener Systems

CAUTION: The manufacturer does not recommend the use of any resin cleaners, nor placement of any resin cleaners into the brine tank. D iagnostic Position: The inlet handle points toward the control valve and the outlet handle points to the center of bypass valve. In the event of a malfunction, however, an overflow line connection will direct the "overflow" to the drain instead of spilling on the floor where it could cause considerable damage. This will provide an adequate anti-siphon trap. No softening/ filtering display when water is flowing B. meter cable disconnected C. restricted/stalled meter turbine D. defective meter B. reconnect PC board C. remove meter and check for debris D. replace meter E. defective PCboard E. past power outage A. reset time of day B. Water technologies water softener manual available. incorrect time of day displayed B. reset time of day 4. Adjust time of regeneration hour with t and s buttons, AM/ PM toggles at 12. Leave at least 6" between the drain line flow control fitting and solder joints. If one of the handles is turned the wrong way, the water you're using is not being filtered by the softener.

Press regen button and unit will proceed to the softening position. Before attempting to make any changes to your system's operation, check with a system professional. 6 Once a manual regeneration is initiated, the unit will go into the FILL position. A negative pressure in the building combined with the softener being in regeneration could cause a siphoning of brine into the building. Unplug transformer to keep the valve in the RINSE position. BYPASS VALVE OPERATION To shut-off water to the system, please position arrow handles as shown in the bypass operation diagram below. Do not "tie" this tube into the drain line of the control valve.

This indicates that the valve was not able to function properly. 1 Locking clip, elbow 1 2 Insert, 5/8" tube OP 3 Nut, 3/4" drain elbow OP 4 Drain elbow assembly, 3/4" NPT 1 5 O-ring 019 1 6 DLFC retainer assembly 1 0. Maybe the Motor is Faulty. 3/4" NPT Proper DLFC orientation directs water flow towards the washer face with rounded edge and lettering. Since salt must be periodically added to the brine tank, it should be located where it is easily accessible. The distance between the drain and the water conditioner should be as short as possible. Programming: Installer Displays/Settings STEP 1 Press next and s simultaneously for 3 seconds. Normal Operation Position: The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve. Please study this manual carefully and understand the cautions and notes before installing. Puronics IQ WholeHouse Water Conditioner Service Manual.

Press regen again to put valve in BACKWASH. The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic Service Wrench, (see page 7). If cleaning doesn't fix the problem, the float mechanism will have to be replaced. Open the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air. Next and regen were pressed to reset the valve.